| Display |
Dual function
0.5" (13 mm) 4-digit LCD |
| Data
hold |
Freezes
displayed reading |
| Sampling
rate |
1 second
approx. |
| Sensors |
Air
velocity/flow sensor: Low friction, ball-bearing vane |
| Temp.
sensor |
Precision
thermistor |
| MAX/MIN |
Memory Record
and view Maximum and Minimum readings |
| Automatic
Power off |
Auto shut off
after 15 minutes to preserve battery life |
| Data
Output |
RS 232 PC
serial interface with 16-bit data stream output |
| Operating
Temp., meter |
32 to 122°F (0
to 50°C); |
| Operating
temp., sensor |
32 to 176°F (0
to 80°C) |
| Operating
Humidity |
Max. 80% RH |
| Power
Supply |
9V battery
(Heavy duty alkaline); optional AC adapter |
| Weight |
1.6 lbs. (700
g) including battery & probe |
| Meter
dimensions |
7 x 2.9
x1.3" (178 x 74 x 33mm) |
|
Sensor dimensions |
0.5"
diameter head; 23.6" (600mm) max antenna length with 9"
(1m) cable |
| . |
|
|
|
| Units
of
Measure |
Range |
Resolution |
Accuracy
(of rdg) |
| ft/min
(feet per minute) |
160 – 2358
ft/min |
1 ft/min |
±
2% |
| m/s
(meters per sec) |
0.80 – 12.00
m/s |
0.01 m/s |
±
2% |
| mph
(miles per hour) |
1.8 – 26.8
mph |
0.1 mph |
±
2% |
| km/h
(kilometers per hour) |
2.8 – 43.2
km/h |
0.1 km/h |
±
2% |
| knots |
1.6 to 23.3
knots |
0.1 knots |
±
2% |
| CFM
(cubic feet per mi) |
0-999,900 ft³/min |
0.001 to 100 |
|
| CMM
(cubic meters per min) |
0-999,900 m³/min |
0.001 to 100 |
|
| Air
Temperature |
32 - 176°F (0
- 80°C) |
0.1°F/C |
1.5°F (0.8°C) |