Tel-Tru® Smoke Gun

                       Persistent white tracer smoke-- perfect for leak tests and tracing air flow patterns.

OUT OF STOCK UNTIL May 2008

15092  Smoke Gun Kit  $189.95   Qty:

15093 Reload Vials, 12/pkg    $68.95   Qty:

Sorry, this product cannot ship by air.  

UPS Ground delivery only to the US and Canadian customers.
 
.
Simply squeeze the rubber bulb handle on the Tel-Tru™ Smoke Gun to produce discrete puffs or a continuous stream of smoke.  The gun combines titanium tetrachloride with moisture in the air to form a dense, persistent white smoke—perfect for tracking airflow patterns or performing leak tests. 

Four reload vials are supplied with each gun kit—each vial supplying 250 to 500 puffs of smoke.  The breech plug on the glass body opens easily for refilling.  Unused chemical can be saved in the gun indefinitely. 

The Tel-Tru™ Smoke Gun Kit comes complete with one Smoke Gun, four reload vials, replacement cotton, instructions, and a high-impact plastic carrying case measuring 9.5" x 6.5" x 3.5".

Caution:  titanium tetrachloride is corrosive. Minute traces of hydrochloric acid will be released during use.  Read and understand all safety information before use.

Indefinite Shelf Life (With Proper Storage)

Easy-To-Use

Widely used by professionals for over sixty years

 

Product Safety Information

This information is provided as a guideline for the use and storage of Smoke Sticks.  It does not replace a Material Safety Data Sheet (MSDS) as defined by federal OSHA requirements.  Click here for Smoke Gun MSDS. 

PRODUCT APPLICATIONS   The T-T Smoke Gun is intended for use in air movement studies.  Specific uses include estimating air speed through animal pens or crates and determining inlet air flow and general air flow patterns.  The dense white smoke produced by the Smoke Gun make it ideal for this application.

PRODUCT SAFETY   The T-T Smoke Gun uses titanium tetrachloride to produce smoke. Titanium tetrachloride is an acid and must be used with caution.  Follow all safety procedures.   

When exposed to moisture in the air, titanium tetrachloride reacts to form smoke containing small quantities of hydrochloric acid, titanium oxychloride and titanium oxides.  Be aware of any problems that small quantities of these chemicals may cause in your specific application.

STORAGE   Store products in a cool, dry place.  Any moisture that comes in contact with titanium tetrachloride will cause the formation of smoke.  Store the  Smoke Gun and reload vials in the carrying case to prevent accidentalaccidental crushing.  Exercise caution to prevent damage to or leakage from this product.  Store in a secure place out of reach of children.  Only those familiar with proper use and safety information should use the Smoke Gun. 

Do not store the Smoke Gun near equipment with metal or electronic parts.  Corrosive acid fumes may cause damage over time.

USAGE GUIDELINES   Use only in a well-ventilated area.  If proper ventilation can not be provided, use a NIOSH approved acid gas respirator, with dust, mist and fume filters.  Avoid inhaling smoke

Avoid contact with smoke.  If skin contact occurs, wash affected area with plenty of soap and water.  Abrasive soaps are most helpful.  Eye protection should always be worn when using these products.  If eyes are affected, flush with water and get medical attention.  Do not take internally.  In case of spill, flood area with water.

PRODUCT DISPOSAL   Dispose of containers and unused titanium tetrachloride in compliance with local, state and federal regulations.

HYGIENE   The T-T Smoke Gun should not be stored or used around food or food products.  Exposed food or drink should be discarded.  Wash hands and face thoroughly before eating, drinking or smoking,

FIRE   Titanium tetrachloride is not flammable or combustible.  However, if in danger of exposure to flame, the Smoke Gun and reload vials should be removed to a safe area to reduce the potential of breaking due to heat. 

TECHNICAL INFORMATION  
  TITANIUM TETRACHLORIDE
  UN Number:  1838
  CAS Registry Number:  7550-45-0
  Formula:  TiCl 4
  Formula Weight:  1897
  Specific Gravity:  1.726 at 68°F/68°F (20°C/20°C)
  Freezing Point:  -22°F (-30°C)
  Boiling Point:  277°F (136.4°C)
  Vapor Pressure: 12.4 mm Hg at 77°F (25°C); 7.1 mm Hg at 60°F (15°C)
  Approximate quantity per stick:   0.05 fl oz 
   
Top of Page
.
.
More Tracer Smoke on MeterMall.com. . . . . 
.
Smoke  Sticks  10 minutes of dense white smoke for checking air flow and leaks. 
Smoke Matches Strike to light.  No flame, but plenty of smoke for about 30 sec.  Box of 20.
Smoke  Puffers 100's of smoke puffs for testing low-velocity air movement.  Disposable. 
Smoke Gun Kit Puffs or streams of dense, persistent smoke. Reusable.
Powder Gun Kit Safe, non-noxious puffs of white powder.  Reusable.
Smoke Pen Continuous or intermittent smoke for low-velocity air testing.  Reusable.
Smoke Emitters Smoke for leak testing and air flow studies.  Variety of volumes  
Smoke Candles Even more smoke for leak testing and air-flow studies.  Several sizes.
 

Air Flow  |  Light Meters |  Psychrometers  Altitude  |  Tracer Smoke

   Gas Detection  |  pH/Water Quality  |   Temp & Humidity  |  Weight/Scales

Data Loggers  |  RPM/Tachometry  |  Pressure

Home | View Cart | Checkout | Customer Care

 
Order by phone:  1-800-969-0114
Fax your RFQ or PO to:  937-642-4691
International customers welcome!