| HOBO® External Sensors
and Input Cables
|
|
 |
Go
directly to ORDER FORM
All of the cables below can be plugged directly
into the external inputs of the HOBO 4-Channel Indoor External, HOBO® H8
Outdoor/Industrial 4-Channel, the HOBO H8 RH/Temp/Light/External, the
HOBO H8 RH/Temp/2x External, or the HOBO Temp/External data loggers.
Accuracy specifications for sensors reflect the combined performance of
the logger and sensor.
External Sensors and Input Cables
- Wide-range temperature
sensors
- Water/Soil temperature
sensors
- High-Accuracy
temperature sensors (TMC6-HB)
- Stainless Steel temperature
probe
- Split-core AC current
sensors
- 4-20 mA cable
- Voltage input cable
-
External sensors and
input cables fit these loggers: HOBO
4-Channel, HOBO
H8 Outdoor/Industrial 4-Channel, HOBO
H8 RH/Temp/Light/External, HOBO
H8 RH/Temp/2x External or HOBO
H8 Temp/External
| Wide-range
temperature sensors (TMCx-HA)
Click
to ORDER |
|
 |
|
Temperature Accuracy and Resolution
|
|
- Range: -40° to 100°C (-40° to 212°F) in air
- Accuracy: ±0.5°C at 20°C (±0.9°F at 70°F),
see plot A below (insert probe 0.9" min.)
- Drift: < 0.1°C (0.2°F ) per year
- Resolution: ±0.41°C at 20°C, (±0.7°F at 70°F),
see plot A below
- Response time in air: 2.5 minutes typical
1m/sec (2.2mph)
- Response time in stirred water: 30 seconds
typical
- 5mm (0.2") diameter sensor (fits in 6.4mm
(1/4") holes)
- Available in 0.3m, 1.8m, 6.0m, and 15.2m (1, 6,
20, and 50 foot) cable lengths
Note: TMCx-HA temperature probes
are not intended for prolonged use in water or moist environments,
especially those with temperatures greater than 30°C (90°F). The
stainless steel tip is waterproof, but water can migrate through the
cable jacket over long term immersion.
These probes can be plugged directly into the
external input jacks of H8 Family loggers to measure temperature in
water or soil.
- Range: 0° to 50°C (32° to 122°F) in water
or soil, -40° to 100°C (-40° to 212°F) in air
- Accuracy: ±0.5°C at 20°C (±0.9°F at 70°F),
see plot A above (insert probe 0.9" min.)
- Drift: < 0.1°C (0.2°F ) per year
- Resolution: ±0.41°C at 20°C (±0.7°F at 70°F),
see plot A above
- Response time in air: 3 minutes typical to 90%
in air moving 1 m/sec (2.2 mph)
- Response time in stirred water: 1 minute
typical to 90%
- Available in 1.8m, 6.1m, and 15.2m foot cable
lengths (6, 20, and 50 foot)
- Housing: Stainless-steel sensor tip
- Probe dimensions: 0.7 cm x 2.5 cm (0.275"
x 1.0")
- Weight: 37g (1.3 oz), 125g (4.4 oz), or 280g
(9.9 oz)
Note: Sensor tip and cable
immersion in fresh water up to 50°C (122°F) for one year; radiation
shield strongly recommended for use in sunlight.
top of page
| High-accuracy
temperature sensors (TMC6-HB)
Click
to ORDER |
|
 |
Temperature Accuracy and Resolution
|
|
- Range: 0° to 44°C (32° to 110°F) in air
- Accuracy: ±0.4°C at 20°C (±0.7°F at 70°F),
see plot B below (insert probe at 1.3" min.)
- Drift: < 0.1°C (0.2°F ) per year
- Resolution: 0.2°C at 20°C (0.3°F at 70°F),
see plot B below
- Response time in air: 4.5 minutes typical to
90% in air moving 1m/sec (2.2mph)
- Response time in stirred water: 1 minute
typical
- 7.6mm (0.3") diameter sensor (fits in
9.5mm (3/8") holes)
- 1.8m cable (6 foot)
Note: TMC6-HB temperature probes
are not recommended for prolonged use in moist environments. Using these
probes in water for longer than the following times can lead to
significant measurement drift and possible sensor failure: 2 weeks
maximum at up to 70°C, 6 weeks maximum at up to 50°C and 10 weeks
maximum at up to 40°C. These sensors can be used in many soils, but not
in those with prolonged high-moisture content.
top of page
- 102mm (4") food-grade stainless steel
probe with pointed tip; 3mm (0.12") diameter
- Range: -40° to 100°C (-40° to 212°F) in air
or water
- Accuracy: ±0.5°C at 20°C (±0.9°F at 70°F),
see plot A above (insert probe 2" min.)
- Drift: < 0.1°C (0.2°F ) per year
- Resolution: 0.41°C at 20°C (0.7°F at 70°F),
see plot A above
- Response time in air: 3 minutes typical to 90%
in air moving 1m/sec (2.2mph)
- Response time in stirred water: 15 seconds
typical
- 1.8m cable (6 foot)
top of page
- Ratio and linear accuracy: ±3.0% of full scale
(includes logger accuracy)
- Input current: AC current, sine wave, single
phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag
- Voltage rating: 600 VAC
- Construction and operating environment: Molded
plastic housing for indoor use per UL508; pivoting leg (leg on CTV-D
and CTV-E units is fully removable).
- 1.8m cable (6 foot)
| Part Number |
Range |
Approx.
Response Time (milliseconds) |
Window |
Outer Length |
Outer Width |
Height |
| CTV-A |
0-20 A ac |
440 |
1.10" x .90" |
2.90" |
2.58" |
1.04" |
| CTV-B |
0-50 A ac |
200 |
1.10" x .90" |
2.90" |
2.58" |
1.04" |
| CTV-C |
0-100 A ac |
100 |
1.10" x .90" |
2.90" |
2.58" |
1.04" |
| CTV-D |
0-200 A ac |
450 |
1.54" x 1.26" |
3.92" |
4.72" |
1.14" |
| CTV-E |
0-600 A ac |
490 |
2.92" x 2.46" |
5.3" |
5.91" |
1.12" |
top of page
- Range: 0 to 20.1 mA
- Accuracy: ±0.1 mA ±1% of reading
- Resolution: 0.4% of full scale
- 457mm (18") cable with 89mm (3.5")
tinned braided wire leads
- 1.8m (6 foot) cable with 13mm (0.5")
tinned braided wire leads.
For voltage input specifications, refer to the HOBO H8
specifications for the model you will be using.
Order
Form
d
|
Description |
Part No. |
$/unit |
Order |
| Wide range
temp sensor - 0.3m (1
ft)** |
TMC1-HA |
$23 |
|
| Wide-range
temp sensor - 1.8m (6
ft) |
TMC6-HA |
$25 |
|
| Wide-range
temp sensor - 6.0m (20
ft)** |
TMC20-HA |
$30 |
|
| Wide-range
temp sensor - 15.2m
(50 ft)** |
TMC50-HA |
$35 |
|
|
Description |
Part No. |
$/unit |
Order |
| Water/Soil
temp sensor - 1.8m (6
ft)** |
TMC6-HD |
$35
|
|
| Water/Soil
temp sensor - 6.0m (20
ft)** |
TMC20-HD |
$40
|
|
| Water/Soil
temp sensor - 15.2m
(50 ft)** |
TMC50-HD |
$45
|
|
|
Description |
Part No. |
$/unit |
Order |
| High-accuracy temperature sensor |
TMC6-HB |
$40 |
|
| Stainless steel temperature
probe** |
TMC6-HC |
$70 |
|
|
Description |
Part No. |
$/unit |
Order |
| 0-20 Amp split-core AC current sensor |
CTV-A |
$84 |
|
| 0-50 Amp split-core AC current sensor |
CTV-B |
$84 |
|
| 0-100 Amp split-core AC current sensor |
CTV-C |
$84 |
|
| 0-200 Amp split-core AC current sensor |
CTV-D |
$100 |
|
| 0-600 Amp split-core AC current sensor |
CTV-E |
$100 |
|
|
Description |
Part No. |
$/unit |
Order |
| 4-20
mA cable (18 inches) |
CABLE-4-20mA |
$13
|
|
| Voltage input cable (6 feet) |
CABLE-2.5-STEREO |
$6 |
|
|
|